Cumulus Linux (NVUE) โ Management
Day-2 inventory, facts and config management for Cumulus Linux (NVUE) data center fabrics (VXLAN/EVPN). Part of the multi-vendor Data Center automation guide.
Setup, key commands & run examples
Describe each Cumulus device once โ role, mgmt IP and VTEP โ so the same workflow targets it and every other vendor in the fabric.
leaf21:
role: leaf
vendor: cumulus
mgmt: 10.0.0.21
vtep: 10.255.0.21
napalm: null # API/gNMI drivenOpen a session to a Cumulus Linux (NVUE) device. This platform is API/gNMI driven, so use its native client.
import requests
# Cumulus Linux (NVUE) โ NVUE REST API
base = "https://10.0.0.23:8765/nvue_v1"
auth = ("cumulus", "secret")
r = requests.get(f"{base}/interface", auth=auth, verify=False)
print(r.json())The day-2 management read-outs you will automate on Cumulus: version, EVPN peers and interface state.
# inventory & health snapshot โ Cumulus Linux (NVUE)
nv show system
nv show interface
nv show vrf default router bgp neighborBest practices
One intent model, many renderers
Keep a single fabric description and render Cumulus config from it โ never SSH in to edit CLI by hand.
Prefer structured APIs
Use the Cumulus structured API (NVUE REST) instead of screen-scraping CLI.
Version your inventory
Treat fabric.yml as the source of truth in git; every change is a reviewable PR.
Idempotent runs
Management scripts should be safe to re-run โ collect, compare, only change what drifted.
Hands-on exercises
Guided practice tasks โ copy the starter snippet, run it against a lab device, and extend it to meet the goal.
Goal: Connect to the leaf, pull version + model and print one inventory row.
import requests
# Cumulus Linux (NVUE) โ NVUE REST API
base = "https://10.0.0.23:8765/nvue_v1"
auth = ("cumulus", "secret")
r = requests.get(f"{base}/interface", auth=auth, verify=False)
# TODO: print hostname, model and OS versionGoal: Compare live interface admin/oper state against the intended list and report mismatches.
intended = {"Ethernet1", "Ethernet2"}
# TODO: read live interfaces and report any intended port that is downCurated videos & guides
Checklist โ pitfalls, gotchas & verification
Common pitfalls
- โขScreen-scraping Cumulus CLI when a structured API exists โ output formats change between releases.
- โขStoring credentials in the script instead of a vault / env vars.
- โขEditing boxes by hand so the inventory no longer matches reality.
Gotchas to watch
- โขCumulus needs its API enabled (NVUE REST) before automation can connect.
- โขManagement VRF: make sure your reachability is over the mgmt VRF, not the data plane.
Verify it works
- โขRe-run the report and confirm every device returns facts.
- โขConfirm the inventory row matches the physical device (model, serial, OS).